High Power Laser Vein Treatment Machine

The SDL-80 is a proven commodity in the industry of laser vein reduction.  Maximum power output is 220 joules per cm2/second (20-30 joules per pulse) 80,000mW QCW, 800-810nm.  The SDL80 has a very efficient 20mm wide beam with a pulse duration of 70ms. Pulse frequency is user adjustable up to 7 emissions per second.


Reduces spider and thread veins quickly and effectively.
Rebuilds skin tone & texture for a radiant youthful appearance.


-Bank Wire/Bitcoin Discount 12.5%-   -Website Issues? Try our Mirror Site-



 Outstanding for the professional Salon & Medi Spa setting. 

Uncomplicated design, fast setup, fully adjustable.


Client Pre-Qualifications: Types 1 through 4 are outstanding candidates. Type 5 will have excellent results, but care must be taken to assure that the laser will not burn the skin. Type 6 should not undergo laser vein removal unless used in conjunction with skin bleaching due to the high risk of burning and hypo/hyperpigmentation issues. If you are unsure of your client's skin type, click here for information.

A recent study compared the diode laser (810 nm) to the 1064 nm Nd:Yag in a prospective, randomized, controlled trial to treat small telangiectatic leg veins in 29 study participants.6 For the study, 2 blinded investigators evaluated the patients at 3 months. Both investigators’ and participants’ assessments found significantly better clearance at 3 months with the diode laser versus the Nd:Yag; however, the diode laser was rated more painful.

References:   Klein A, Buschmann M, Babilas P, Landthaler M, Baumler W. Indocyanine green-augmented diode laser therapy vs. long-pulsed Nd:Yag (1064 nm) laser treatment of telangiectatic leg veins: a randomized controlled trial. Br J Dermatol. 2013;169(2):365-673.


Powerful, Versatile and Affordable Laser Technology

SDL80 Vein Reduction Kit Comes With:  Professional Diode Laser Hand Piece 220jcm2 energy density (fluence), key lockout safety switch, laser 'enabled' system status LED, adjustable intensity, 2 pair of laser protection eyewear, 50ml carbon dye gel, 50ml of 3% lidocaine pre-treatment gel, 50ml of post treatment vein reduction gel and instructions.

he SDL80 Laser System has a very comfortable and versatile handpiece. A powerful 5cfm positive displacement micro-fan keeps the semiconductor cool during usage, which increases the power, performance, and overall life expectancy of the laser.


The SDL-80 Diode Laser System is specifically designed to deliver highly concentrated photon energy directly through the skin to effectively destroy laser hair removal productsunwanted spider veins and to shrink large varicose veins.  Each power pulse has an effective treatment area of 2cm wide and feels like a brief pinch.  Very few patients would describe the procedure as 'painful'. 

This system is also excellent for general dermatology procedures, age spot removal, wrinkle reduction, laser resurfacing, and more. The technician may use it for tattoo removal on most dark inks. It produces four times the adequate power required for laser hair removal procedures (including photo shaving on hair growth types 3-6: brown and black).


If you are using cosmetics on the area to be treated containing retinoids (retin a, tretinoin, altinac, avita, trans retinoic acid, vitamin A acid, tazorac, adapalene, differin), or AHA (alpha hydroxyl acids, glycolic acid) stop using the cosmetic at least two days before the laser treatment. If you have been taking Accutane (isotretinoin) you should be off of it for two to six months before laser treatment. If you have had a microdermabrasion on the area to be treated it is best to wait seven to ten days before laser treatment.

  • Energy Density (fluence): 220 jcm2/sec. maximum (22-26 jcm2/pulse)

  • Pulse Frequency: User adjustable from 1, 3, 7 pulses/second

  • Pulse Duration: Factory Preset 70ms

  • Beam Size and Shape: 20 mm line optics

  • Treatment Time for Facial Area:  3-5 minutes

  • Treatment Time for Legs or Torso:  10-20 minutes

  • PDF Instructions: Link

  • Video Instructions: Download

  • Topical Acc. Data Sheets:  1, 2, 3

  • Certificate of Conformity:  FCC, CDRH, CE low voltage directive. 651044474687

  • Controller Size: 6" H x 8" W x12" L (13cm x 18cm x 25cm).  Weight: 7lbs (3kg).


Also Approved For:  Permanent Hair Reduction, Skin Toning, Body Sculpting, Photo Rejuvenation, Hyper Pigment - Age Spot Removal, Tattoo Removal, Wrinkle Reduction, Scar - Stretch Mark Reduction, Psoriasis, Rosacea, Sun Damage, Blemish (mole, wart, skin tag) Removal, Nail Fungus Treatment and More.  These treatment options are covered in literature sent with the system.


90 Day Unconditional Money-Back Guarantee


Warranty Information:  To the original purchaser, the above item will arrive without damage or defect in material or workmanship. Should your system arrive damaged or in otherwise incomplete/unacceptable condition please refer to the warranty repair card in your instruction packet to expedite the return. This warranty is valid for 12 calendar months from the date of purchase. Additional years may be purchased for $9.95 each up to 5 years. Refer to the warranty registration card included with your packet for more information.


Guaranteed Utility Compatibility.  110-240 Volts.  All kits are sent with corresponding input voltage, hertz and plug style for the country of destination. If you have special requirements, please note them in the checkout section of your purchase.


Legal Disclaimer:   Images on this page are for example purposes only and do not necessarily reflect results that will be achieved on all clients and persons. Typical results from laser applications are rated in terms of 'improvement' and not 'cure'. This equipment is not intended to diagnose, treat or cure any disease.


-Products-  -Company-  -Privacy Policy -Tech Support-  -Ordering Online-  -Home Page-

Can't find what you are looking for?  Search the Bio-Avance online catalog below.